Precision Measurement Engineering, Inc.
The Test tab of the SCAMP Control Dialog allows users to perform
tests of SCAMP and to view results. The Test tab is shown below.

Analog Test
SCAMPs electronic circuits contain a A/D converter and also an
offset and gain amplifier. The analog test programs the gain = 1 and ramps the offset
through its full range while measuring the analog voltage produced with the A/D. This
effectively tests the A/D converter and the offset section of the offset and gain
amplifier. Channel electronics and sensors are not tested.
The Channel Test causes SCAMP to acquire a short amount of selected
channel readings that are uploaded and displayed by the SCAMP Control Dialog. This is
useful to establish that an individual channel is operating correctly.
SCAMP activates its release motor for 2 seconds in response to this test.